Hopp over seksjon - Til hovedinnhold - Topp
145 - 420kV / 2000 - 3150 A
Type TPF pantograph disconnector is originally a design from Sprecher & Schuh AG. and has been produced in Norway since 1963.
EB Elektro has further developed the disconnector, among other things movable contact adapters with silver-plated copper bushings, which results in less corrosion and lower contact resistance.
The TPF pantograph disconnector has been supplied on a large scale to both the Norwegian and the international markets.
We can inspect and repair, as well as supply all spare parts to, disconnectors supplied from 1963 until today.
| Rated voltage | Ur (kV) | 145 | 170 | 245 | 300 | 362 | 420 | |
| Lightning Impulse Withstand Voltage: | |
|
|
|||||
| - to earth | TE | Ud (kV) | 650 | 750 | 1050 | 1175 | 1425 | |
| - across the isolating distance | AID | Ud (kV) | 750 | 860 | 1050 | 1175 | 1425 | |
| Power Frequency Withstand Voltage: | |
|||||||
| - to earth | TE | Ud (kV) |
275 | 325 | 460 | 380 | 450 | 520 |
| - across the isolating distance | AID | Ud (kV) |
315 | 375 | 530 | 435 | 520 | 610 |
| Switching Impulse Withstand Voltage: | |
|
||||||
| - to earth | TE | Up (kV) | - | - | - | 850 | 950 | 1050 |
| - across the isolating distance | AID | Us (kV) | - | - | - | 700 (+245) |
800 (+295) |
900 (+345) |
| Current and Short circuit ratings | *1600A - 125 kA peak - 50 kA/2 sec. *2500A - 125 kA peak - 50 kA/2 sec. *3150A - 125 kA peak - 50 kA/2 sec. |
| Voltage (kV) | 145 | 170 | 245 | 300 | 362 | 420 |
| A | 4570 | 5895 | 8515 | |||
| B | 1590 | 2390 | 3230 | |||
| C | 1580 | 1700 | 2300 | 2650 | 3150 | 3350 |
| D | 3295 | 4430 |

EB Elektro AS - Elektroveien 8 - N-3300 Hokksund - Tlf.: +47 32 25 01 20 - Fax: +47 32 25 01 21 - E-post: post@eb-elektro.no